Parallel Factory MES User Guide Overview 日本語

Troubleshooting

Common error messages and what to do about them. Look for the text shown in the red bar.

Messages are shown here as they appear when the screen language is English. With the screen in Japanese, they appear in Japanese; see the Japanese version of this page.

Sign-in and accounts

Symptom / message Cause and what to do
The user name or password is incorrect. Check what you entered. Upper and lower case are distinguished
The account is temporarily locked. Please wait a while and try again. The account was locked because sign-in kept failing. Try again after a while, or ask an administrator to reset your password
The sign-in screen says “Initial setup is required.” No users are registered. Create the initial administrator from the link
The dashboard says you are still using the initial password Change your password from the link. The message keeps appearing until you do
Setup failed. Check the password requirements (8+ characters, lowercase letters and digits). The password does not meet the condition: at least 8 characters, containing a lowercase letter and a digit
Initial setup has already been completed. Users already exist. Sign in from the sign-in screen as usual
The button for the operation you want is not on the screen Your roles do not have the permission. Check Roles and permissions and ask an administrator to give you the role

Manufacturing orders and release to processes

Message What to do
An order with status ‘…’ cannot be released (only approved orders). Approve it first
Release to processes fails / no work orders are created No routing (BOP) is registered for the product. Register one in Master data
An order with status ‘…’ cannot be changed (after release it can only be canceled). The contents cannot be changed after release. Cancel it and register it again
The item ID does not exist or is inactive. The product has been deactivated. Check it in Master Data
A rework order requires the source order ID (sourceOrderId). Create rework orders from the “Rework” action in Nonconformances

Dispatching

Message What to do
Skill ‘…’ of user ‘…’ has expired. Update the expiry date under Master Data → Users → Skills & Qualifications (this appears when dispatching, starting work, and registering maintenance records and inspection results)
The assigned operator does not exist or is inactive. The user has been deactivated
A work order with status ‘…’ cannot be dispatched. Work orders that have been started or later cannot be dispatched
The Worker drop-down shows only “Unassigned” You do not have permission to view the user list (system administrator). You can still assign only the equipment and start sequence

Recording results

Message What to do
A record for the final process requires a put-away location (outputLocationId). Choose the Put-away location before registering
Backflush is not possible because the planned materials are missing (no MBOM at release). Register the MBOM in Master data and recreate the order, or untick Backflush
Cannot backflush because no planned materials are consumed at this step (sequence …). No components are used in this process. Untick Backflush. If the process does use components, correct the consuming step in the MBOM and recreate the order
The consuming step (sequence …) of MBOM material ‘…’ is not in the routing of item ‘…’. Correct the MBOM or the routing. Correct the consuming step in the MBOM or the routing, and then release
The total of good and defective quantities must be greater than 0. Enter a quantity in one of them
Results cannot be recorded for a work order with status ‘…’. It has already been approved or canceled
A work order with status ‘…’ cannot be approved (only completed work orders). Register results to make it “Completed”, then approve it
Backflushing fails with an insufficient inventory error Prepare component inventory by receiving or by registering results in the previous process

Inventory and receiving

Message What to do
The receipt cannot be canceled because the stock has changed since receiving (use a quantity adjustment instead). Correct it with Adjust quantity on the Inventory screen
No adjustment is needed because the quantity is the same as the current quantity. The quantity after adjustment is the same as the current quantity
Lots of different items cannot be merged. Only inventory of the same product in the same location can be merged
The source and target lots are the same. Specify a different lot as the target
The source lot has no stock. The inventory of the lot is 0
Specify a new item ID (item transfer) or a new lot number (lot transfer). Enter either the target item or a new lot number
Select a lot. Choose a lot in “Select stock” on the Operations tab before operating

Picking, issuing and shipping

Message What to do
Creating a picking order fails (insufficient inventory) Prepare inventory by receiving or with results of the previous process
Process issue requires a valid work order ID (workOrderId). Choose the work order to issue to
Shipping picking requires a valid shipping order ID (shippingOrderId). Choose the shipping order to issue to
Shipping is not possible because there is no approved shipment judgment (approved or special acceptance) (H-10-10). Ask quality assurance staff to register and approve a shipment judgment. Goods cannot be shipped with an “On hold” judgment
A shipping order with status ‘…’ cannot be executed. It has already been completed or canceled

Inspections and nonconformances

Message What to do
No inspection criteria match the target. Register inspection items or specify itemIds. In Master Data → Inspection Items, register items that match the inspection type, product and process
In-process inspection requires a target work order ID (targetWorkOrderId). Choose the work order for an in-process inspection
A target lot ID (targetLotId) is required. Specify the lot for inspections other than in-process inspections
Inspection item ‘…’ cannot be judged automatically from specification limits. Specify judgment. Choose Pass or Fail in “Judgment (manual)” on that row
N inspection items have no results. Register results for all items before judging. Enter results for every item before judging
An approved inspection cannot be corrected. It cannot be corrected after approval. Issue a reinspection order
Enter a correction reason. A reason is required to correct inspection results
A closed nonconformance cannot be given an action instruction. Raise a new nonconformance
A nonconformance cannot be approved before an action is instructed. Instruct the action type first

Equipment maintenance and tools

Message What to do
Stop and failure records require a stop cause (stopCause) (B-40-20-02). Enter the stop cause
Specify either a target equipment ID or a target tool ID, not both. Choose only one of equipment or tool
Record either the usage count or the usage time. Tool usage records need either a count or a time
The operation summary shows no figures Only operation records with an end time are included
An order cannot be created from a maintenance plan with status ‘…’. Orders can be issued only from plans in the “Planned” status

Scanning and printing

Symptom What to do
The camera is unavailable (unsupported browser or permission denied). An HTTPS connection is required (localhost is the exception). Use a USB barcode reader or type the code
You denied the camera permission once Change the camera permission to “Allow” from the icon in the browser’s address bar
The report page does not open A pop-up blocker may be stopping it. Allow pop-ups for this site in the browser settings
You want to save as PDF Choose “Save as PDF” as the printer in the print dialog

Installation and startup

| Symptom | What to do | |—|—| | Starting the ZIP edition shows “Windows protected your PC” | This warning is attached to files obtained from the internet. You can start it with More info → Run anyway. To stop it appearing every time, check Unblock in the properties of the ZIP file before extracting, and extract it again | | On Linux, ./start.sh fails with “Permission denied” | ZIP files do not keep execute permissions. Start it with sh start.sh (it gives the program execute permission when it starts) | | The ZIP edition closes immediately after starting / says the port is in use | Another application is using port 5000. Change the port with MESAPP_URLS before starting (for example set MESAPP_URLS=http://0.0.0.0:5100) | | Data disappeared after recreating the Docker container | /data is not a volume. Start it with -v mesapp-data:/data (Server deployment and settings) |

Display and connection

Symptom What to do
The screen stays at “Loading…” The server has stopped or the network is disconnected. Check with your administrator
You are suddenly returned to the sign-in screen while working The access token has expired. Sign in again. The expiry time can be changed in the settings
You cannot connect from another PC The server’s firewall must allow incoming connections on the port (Server deployment and settings)

If the problem is still not solved

When you contact your administrator, giving the following information makes things go smoothly.

  • The screen you were using and the button you pressed
  • The exact error message shown on the screen
  • The numbers involved (order number, work order number, lot number and so on)
  • The date and time of the operation and the signed-in user name